The XFCG5 includes an Integral Multivariable Transducer (XIMV) to measure differential pressure, static pressure and temperature from a single differential pressure meter run. The XIMV is housed in a shielded, environmentally protected enclosure which is mounted inside the flow computer enclosure and is characterized and calibrated at Totalflow’s factory. Multi-tube capability is available in each unit and is easily invoked with a few configuration changes and interface connection to external transducers, either digital or analog.
The processing and memory capability of the XFCG5 allows the user to run more applications faster than ever before. Up to twenty (20) AGA3 measurement tubes performing full calculations once a second or eight (8) wells with fully configured control and measurement applications for liquid and gas.